This list contains the ADN Dangerous Goods List, as implemented by the European Union's Directive 2008/68/EC. This Directive establishes rules for the safe transport of dangerous goods between EU countries by road (ADR) and inland waterways (ADN), and the regulations concerning the international carriage of dangerous goods by rail (RID). The specific CAS linked as members on this list are representative examples, but not exhaustive.

SOLIDS CONTAINING TOXIC LIQUID, N.O.S.;TOXIC BY INHALATION LIQUID, CORROSIVE, N.O.S. with an LC50 lower than or equal to 1000 ml/m3 and saturated vapour concentration greater than or equal to 10 LC50;TOXIC BY INHALATION LIQUID, CORROSIVE, N.O.S. with an LC50 lower than or equal to 200 ml/m3 and saturated vapour concentration greater than or equal to 500 LC50;TOXIC BY INHALATION LIQUID, FLAMMABLE, CORROSIVE, N.O.S. with an LC50 lower than or equal to 1000 ml/m3 and saturated vapour concentration greater than or equal to 10 LC50;TOXIC BY INHALATION LIQUID, FLAMMABLE, CORROSIVE, N.O.S. with an LC50 lower than or equal to 200 ml/m3 and saturated vapour concentration greater than or equal to 500 LC50;TOXIC BY INHALATION LIQUID, FLAMMABLE, N.O.S. with an LC50 lower than or equal to 1000 ml/m3 and saturated vapour concentration greater than or equal to 10 LC50;TOXIC BY INHALATION LIQUID, FLAMMABLE, N.O.S. with an LC50 lower than or equal to 200 ml/m3 and saturated vapour concentration greater than or equal to 500 LC50;TOXIC BY INHALATION LIQUID, N.O.S. with an LC50 lower than or equal to 1000 ml/m3 and saturated vapour concentration greater than or equal to 10 LC50;TOXIC BY INHALATION LIQUID, N.O.S. with an LC50 lower than or equal to 200 ml/m3 and saturated vapour concentration greater than or equal to 500 LC50;TOXIC BY INHALATION LIQUID, OXIDIZING, N.O.S. with an LC50 lower than or equal to 1000 ml/m3 and saturated vapour concentration greater than or equal to 10 LC50;TOXIC BY INHALATION LIQUID, OXIDIZING, N.O.S. with an LC50 lower than or equal to 200 ml/m3 and saturated vapour concentration greater than or equal to 500 LC50;TOXIC BY INHALATION LIQUID, WATER-REACTIVE, FLAMMABLE, N.O.S. with an LC50 lower than or equal to 1000 ml/m3 and saturated vapour concentration greater than or equal to 10 LC50;TOXIC BY INHALATION LIQUID, WATER-REACTIVE, FLAMMABLE, N.O.S. with an LC50 lower than or equal to 200 ml/m3 and saturated vapour concentration greater than or equal to 500 LC50;TOXIC BY INHALATION LIQUID, WATER-REACTIVE, N.O.S. with an LC50 lower than or equal to 1000 ml/m3 and saturated vapour concentration greater than or equal to 10 LC50;TOXIC BY INHALATION LIQUID, WATER-REACTIVE, N.O.S. with an LC50 lower than or equal to 200 ml/m3 and saturated vapour concentration greater than or equal to 500 LC50;TOXIC LIQUID, CORROSIVE, INORGANIC, N.O.S.;TOXIC LIQUID, CORROSIVE, ORGANIC, N.O.S.;TOXIC LIQUID, FLAMMABLE, ORGANIC, N.O.S.;TOXIC LIQUID, INORGANIC, N.O.S.;TOXIC LIQUID, ORGANIC, N.O.S.;TOXIC LIQUID, OXIDIZING, N.O.S.;TOXIC LIQUID, WATER-REACTIVE, N.O.S.;TOXIC SOLID, CORROSIVE, INORGANIC, N.O.S.;TOXIC SOLID, CORROSIVE, ORGANIC, N.O.S.;TOXIC SOLID, FLAMMABLE, INORGANIC, N.O.S.;TOXIC SOLID, FLAMMABLE, ORGANIC, N.O.S.;TOXIC SOLID, INORGANIC, N.O.S.;TOXIC SOLID, ORGANIC, N.O.S.;TOXIC SOLID, OXIDIZING, N.O.S.;TOXIC SOLID, SELF-HEATING, N.O.S.;TOXIC SOLID, WATER-REACTIVE, N.O.S.

ecnumber: - casnumber: -
Class
6.1
Labels
6.1+5.1
Packing Group
II
UN No. or ID no.
3086
Classification code
TO2
Equipment required
PP

EP

Limited and excepted quantities Excepted quantities
E4
Limited quantities
500 g
Number of blue cones/lights
2
Special provisions
274

802