Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Experimental test result following standard method.
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
139.3 °C
Atm. press.:
975.7 hPa
Remarks on result:
other: Non flammable

Method Details

Observations

Remarks if, any

Flash point apparatus

·    Abel’s flash pt apparatus

·    Pensky-Martens flash point apparatus

Pensky-Martens flash point apparatus

 

Quantity of chemical used

g/ml

       5.007

 

Ignition source

Gas lighter/flame

Gas lighter

 

Atmospheric pressure

hPa

975.7hPa

 

 Mean Flash point (RESULT)

°C

139.3 °C

 

Interpretation of results:
other: not classified based on CLP criteria
Conclusions:
The flash point determination of Dimethyl sulphone (CAS No. 67-71-0) was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was found to be 139.3°C at 975.7hPa.
Executive summary:

The flash point determination of test chemical was done by closed cup method using Pensky-Martens Flash Point Apparatus. The mean flash point of the test chemical was determined to be 139.3°C at 975.7 hPa.

Description of key information

The flash point determination of test chemical was done by closed cup method using Pensky-Martens Flash Point Apparatus. The mean flash point of the test chemical was determined to be 139.3°C at 975.7 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
139.3 °C

Additional information

The flash point determination of test chemical was done by closed cup method using Pensky-Martens Flash Point Apparatus. The mean flash point of the test chemical was determined to be 139.3°C at 975.7 hPa.

Based on the data from reliable handbook and authoritative database, the flash point of test chemical was observed to be 143 °C.

Thus, for the purpose of chemical safety assessment we will consider the key study value which is reported as 139.3°C at 975.7 hPa.