Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
4/13/2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
non-GLP in house method
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Flash point:
104 °C
Atm. press.:
101 300 Pa
Interpretation of results:
other: not a flammable liquid
Remarks:
according to EU CLP (EC no. 1272/2018 and its amendments)
Conclusions:
The Flash Point of Ethyl Phenyl Glycidate is 104°C in a reliable non-GLP study using the closed cup method equivalent to the EU Method A.9 (Flash-Point).
Executive summary:

The Flash Point of Ethyl Phenyl Glycidate at atmospheric pressure of 101360 is 104°C using the closed cup method study equivalent to EU Method A.9 (Flash-Point).

Description of key information

The Flash Point of Ethyl Phenyl Glycidate at atmospheric pressure of 101360 is 104°C using the closed cup method study equivalent to EU Method A.9 (Flash-Point).

Substance is or is not considered a flammable liquid because the flash point less than or exceeds 60°C based on the classification criteria for flammable liquids (EU CLP, EC 1272/2008 and its amendments).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
104 °C

Additional information