Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP-Guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
yes (incl. QA statement)
Remarks:
UK GLP Monitoring Authority
Type of method:
equilibrium method closed cup
Flash point:
59 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: 59 ±2 °C

Results of the flash point determination are shown in teh following table:

Temperature (°C) Observations
24 No flash
29 No flash
34 No flash
39 No flash
44 No flash
49 No flash
54 No flash
59 A blue flash spread across the sample cup
54 (fresh sample) No flash
55 No flash
56 No flash
57 No flash
58 No flash
59 A blue flash spread across the sample cup
59 (fresh sample) A blue flash spread across the sample cup
59 (fresh sample) A blue flash spread across the sample cup
57 (fresh sample) No flash
57 (fresh sample) No flash
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria

Description of key information

59 ± 2 °C at 101.325 kPa 
(EU method A.9, closed cup equilibrium method)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
59 °C

Additional information