Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Being ignited with the flame of a teclu burner, the test item started to melt after a few seconds. Melting, but no ignition

was observed.

Therefore, the test item should be considered as not highly flammable.

Conclusions:
Not highly flammable.
Executive summary:

The test item does not ignit and is to be considered as not flammable.

Description of key information

not highly flammable

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

The test item has not to be considered as flammable.

Justification for classification or non-classification

No classification due to result of experimental test