Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Description of first aid measures
Inhalation
If aerosol or mists are formed:
If necessary: Provide with fresh air.
Skin contact
Wash off with plenty of water and soap.
Eye contact
Rinse thoroughly with plenty of water keeping eyelid open.
In case of persistent discomfort: Consult an ophthalmologist.
Ingestion
Have the mouth rinsed with water.
After absorbing large amounts of substance / In case of discomfort: Supply with medical care.
Most important symptoms and effects, both acute and delayed
Symptoms
None known
Hazards
None known
Indication of any immediate medical attention and special treatment needed
After absorbing large amounts of substance:
administration of activated charcoal.
Acceleration of gastrointestinal passage

Fire-fighting measures

Extinguishing media

Suitable extinguishing media: Water spray jet
Foam
Carbon dioxide (CO2)
Dry powder

Unsuitable extinguishing media: High volume water jet
Special hazards arising from the substance or mixture
May be released in case of fire: carbon monoxide, carbon dioxide, organic products of decomposition.
In case of fire cool endangered containers with water.
Advice for firefighters
Water used to extinguish fire should not enter drainage systems, soil or stretches of water.
Ensure there are sufficient retaining facilities for water used to extinguish fire.
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.
In case of fire: wear a self contained respiratory apparatus

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Use personal protective equipment.
Keep away from sources of ignition - No smoking.
Ensure adequate ventilation.
Environmental precautions
Do not allow entrance in sewage water, soil stretches of water, groundwater, drainage systems.
Methods and material for containment and cleaning up
Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Fill into marked, sealable containers.
To be disposed of in compliance with existing regulations

Handling and storage

Precautions for safe handling
Assure sufficient ventilation.
Application, processing: Provide good ventilation or extraction
Conditions for safe storage, including any incompatibilities
Advice on protection against fire and explosion
Take precautionary measures against static discharges.
Keep away from sources of ignition - No smoking.
Explosion protection equipment required.
Danger of explosion from residual product fumes; therefore avoid spark production through cutting, grinding, or welding work in the area of the container.
When repairs of the production system are to be made (e.g. welding work), the section to be repaired must be essentially free of product.
Storage
Keep containers tightly closed in a cool, well-ventilated place.
Protect from moisture.
German storage class
3 - Flammable liquids

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN 1993
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN 1993
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN 1993
Shipping information
Proper shipping name and description:
FLAMMABLE LIQUID, N.O.S.(Tri(isopropoxy)vinylsilane)
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN 1993
Shipping information
Proper shipping name and description:
FLAMMABLE LIQUID, N.O.S.(Tri(isopropoxy)vinylsilane)
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters

Other information
Contains no substances with occupational exposure limit values.

Exposure controls
Engineering measures
Provide adequate ventilation.
Personal protective equipment
Respiratory protection
In case of dusts/vapours/aerosols being formed or if the limit values like TLV are exceeded:
use respiratory equipment with suitable filter (filter type A) or wear a self contained respiratory apparatus
Use only respiratory protection equipment with CE-symbol including four digit test number.
The filter class for the respirator must be suitable for the maximum expected contaminant concentration (gas/vapour/aerosol/particulates) that may arise when handling the product. If this concentration is exceeded, self-contained breathing apparatus must be used.
Note time limit for wearing respiratory protective equipment.
Hand protection
Glove material for example, butyl-rubber
Material thickness 0,5 mm
Break through time >= 480 min
Glove material for example, Fluorinated rubber (Viton)
Material thickness 0,4 mm
Break through time >= 480 min
Selection of protective gloves to meet the requirements of specific workplaces.
Suitability for specific workplaces should be clarified with protective glove manufacturers.
The information is based on our own tests, references from the literature and information from glove manufacturers, or derived by analogy with similar materials.
Please observe that the daily duration of usage of a chemical protective glove is in practice far shorter due to the many influencing factors (e.g. temperature, mechanical strain on the glove material) than the permeation time determined acc. EN 374.
Eye protection
Safety glasses
Skin and body protection
Flame retardant antistatic protective clothing.
Hygiene measures
When using, do not eat, drink or smoke. Wash face and/or hands before break and end of work.
Remove contaminated or saturated clothing.
Wash contaminated clothing before re-use.
Protective measures
Handle in accordance with good industrial hygiene and safety practice.
The personal protective equipment used must meet the requirements of directive 89/686/EEC and amendments (CE certification).
If workplace exposure limits are exceeded and/or larger amounts are released (leakage, spilling, dust) the indicated respiratory protection should be used.
If there is the possibility of skin/eye contact, the indicated hand/eye/body protection should be used.
Avoid contact with the skin and the eyes.
Do not breathe in vapours or aerosols.

Stability and reactivity

Reactivity
No dangerous reaction known under conditions of normal use
Chemical stability
Stable under recommended storage conditions
Possibility of hazardous reactions
Possibility of hazardous reactions Risk of spontaneous ignition if exposed to air and elevated temperatures.

Conditions to avoid
Keep away from heat and sources of ignition.
Protect from moisture.
Incompatible materials
Water
Hazardous decomposition products
2-propanol in case of hydrolysis

Disposal considerations

Product
With respect to local regulations, e.g. dispose of to suitable waste incineration plant.
Uncleaned packaging
Do not reuse empty containers and dispose of in accordance with the regulations issued by the appropriate local authorities.
If there is product residue in the emptied container, follow directions for handling on the container's label.
Incorrect disposal or reuse of this container is illegal and can be dangerous.
Other countries: observe the national regulations.
Waste Key Number
No waste key number as per the European Waste Types List can be assigned to this product, since such classification is based on the (as yet undetermined) use to which the product is put by the consumer.
The waste key number must be determined as per the European Waste Types List (decision on EU Waste Types List 2000/532/EC) in cooperation with the disposal firm / producing firm / official authority.