Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 July 2010- 30 July 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: This study has been performed according to OECD and EC guidelines and according to GLP principles.
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: by loss of weight or by trapping vaporisate
Key result
Temp.:
20 °C
Vapour pressure:
0 Pa
Conclusions:
The isothermal thermogravimetric effusion method was chosen for the determination of the vapour pressure of Decanoic acid, mixed esters with heptanoic acid, octanoic acid and trimethylolpropane.

The vapour pressure of the test substance at 20°C (293K) was 7.55 x 10E-6 Pa = 5.66 x 10E-8 mm Hg.

Description of key information

Determined in accordance with OECD Guideline 104.

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
20 °C

Additional information

The isothermal thermogravimetric effusion method was chosen for the determination of the vapour pressure of Decanoic acid, mixed esters with heptanoic acid, octanoic acid and trimethylolpropane.

The vapour pressure of the test substance at 20°C (293K) was 7.55 x 10E-6 Pa = 5.66 x 10E-8 mm Hg.