Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14 October 2011 - 15 March 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to EU method A.9 and DIN EN ISO 2719

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002. Remark: DIN EN ISO 2719
Type of method:
non-equilibrium method closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Amines, C12-14-alkyldimethyl
EC Number:
283-464-9
EC Name:
Amines, C12-14-alkyldimethyl
Cas Number:
84649-84-3
Molecular formula:
R-N(Me)2, whereas R= C12-14-alkyl (even numbered, unbranched, saturated)
IUPAC Name:
N,N-dimethyl-C12-14-(even numbered)-alkyl-1-amines

Results and discussion

Flash point
Flash point:
121 °C
Atm. press.:
101.3 kPa

Any other information on results incl. tables

The measurement gave the following results:

Measurement

Result

Norm conformity

#1

120.6

Yes

#2

120.7

Yes

The flash point is taken as the rounded mean value, 121 °C.

The mean atmospheric pressure was 100.6 kPa; the result quoted is corrected to standard atmospheric pressure, 101.3 kPa.

Based on the general experience with the method, the error is quoted as ± 2 °C.

Applicant's summary and conclusion

Conclusions:
The flash point of the test item is 121 ± 2 °C at 101.3 kPa.
Executive summary:

The flash point of the test substance was determined according to EU method A.9 and DIN EN ISO 2719 using a Pensky-Martens apparatus. At 101.3 kPa, the flash point is 121 +/- 2 °C.