Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2 October 1991 - 16 January 1992
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of the relevant results.
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
yes
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test material is non-flammable with respect to this test.
Executive summary:

The flammability of the test material was investigated in accordance with the standardised guideline EC Method A.10.

The test material was formed into a pile 250 mm long and several attempts were made to ignite one end of the pile using a butane/air flame.

The test material did not ignite. It is non-flammable with respect to this test.

Description of key information

The test material is non-flammable. 

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability of the test material was investigated in accordance with GLP and the standardised guideline EU Method A.10.

The test material was formed into a pile 250 mm long and several attempts were made to ignite one end of the pile using a butane/air flame.

The test material did not ignite. It is non-flammable with respect to this test.

Justification for classification or non-classification

In accordance with the criteria for classification as defined in Annex I, Regulation 1272/2008, the test material does not require classification as it does not meet the conditions specified for Flammable Solids.