Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1996-05-13 - 1996-05-15 (experimental phase)
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1996

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
EEC Directive 92/69 (which constitutes Annex V of Council Directive 67/548/EEC)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Test material form:
solid: particulate/powder

Results and discussion

Flammable solids
Key result
Test procedure:
burning rate test: preliminary screening test
Moisture (wt %):
0.1
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Polyperin Y could not sustain a burning reaction during the preliminary test (contact time of about 2 minutes). No main test was performed. In conclusion, Polyperin Y is not "highly flammable" according to the criteria of the guideline.
Executive summary:

The determination of the flammability of the test item was performed in accordance with the EEC Directive 92/69, Part A, Methods for the determination of physico-chemical properties, A.10 "Flammability (solids)", EEC Publication No. L383, December 1992.

Polyperin Y could not sustain a burning reaction during the preliminary test (contact time of about 2 minutes). No main test was performed.

In conclusion, Polyperin Y could not sustain a burning reaction during the preliminary test and is therefore not "highly flammable" according to the criteria of the guideline.