Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
13 November 2000
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: Directive 92/69/EEC, A.8 (HPLC method) (EEC publ.no L383, Dec 1992)
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Version / remarks:
(1989)
GLP compliance:
yes
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
1.7
Temp.:
20 °C
pH:
6
Remarks on result:
other: major component
Type:
log Pow
Partition coefficient:
0.6
Temp.:
20 °C
pH:
6
Remarks on result:
other: minor component
Details on results:
estimated log Pow based on Rekker Calculation method: 3.76
estimated pKa based on Perrin's Calculation method: acidic groups (phenol) 8.38, basic groups (ARCONHR) -1.92

Two peaks were observed in the chromatogram and it was assumed that the large peak derives from the major component of BMH whereas the small peak derives from a minor component in BMH. All test substance related peaks eluted well within 10 minutes.

The results of the Calculation method and the HPLC method are not in agreement. Since the HPLC method is a more accurate method than the Calculation method, the result of the HPLC method is reported as the partition coefficient (n-octanol/water), Pow, of BMH.

The t0 (the retention time of the unretarded component) was determined to be 0.866 minutes as a mean value of both measurements (i.e. 0.866 and 0.866 minutes).

Substance

tr1

k’

log k’

log Pow

Pow

 

 

 

 

 

 

Reference substance

 

 

 

 

 

 

 

 

 

 

 

 Ethylmethylketone

1.307

0.509

-0.293

0.3

 

 Nitrobenzene

2.074

1.395

0.145

1.9

 

 Toluene

3.453

2.987

0.475

2.7

 

 Bromobenzene

3.792

3.378

0.529

3.0

 

 1,4-dichlorobenzene

4.934

4.697

0.672

3.4

 

 Biphenyl

5.781

5.676

0.754

4.0

 

 

 

 

 

 

Test substance

 

 

 

 

 

 

 

 

 

 

 

 minor component

1.410

0.628

-0.202

0.62

3.9

 major component

2.010

1.320

0.121

1.72

48

 

 

 

 

 

 

1      Mean value of the retention times of two chromatograms.

2      Interpolated from the regression line: log k’ = 0.297*log Pow- 0.378 (r=0.994, n = 6)

Conclusions:
The HPLC method (with UV-detection) was used to determine the n-octanol/water partition coefficient of BMH. At 20.0 +/- 0.5°C , the Pow value for the major component in BMH is 48 (log Pow = 1.7) and for the minor component in BMH the Pow is 3.9 (log Pow = 0.6).

Description of key information

log Kow of BMH is 1.7 (EC A.8, OECD 117: HPLC-UV).

Key value for chemical safety assessment

Log Kow (Log Pow):
1.7
at the temperature of:
20 °C

Additional information

Kow of BMH is 48.

In water, BMH hydrolyses into two compounds, being 3-Hydroxy-2 -naphthoic acid, hydrazine (HNH; CAS no. 5341-58-2) and Methyl isobutyl ketone (MIBK; CAS no. 108-10-1), with a DT50 of 28 hours under environmentally relevant conditions. The Kow of these compounds have been calculated with the KOWWIN program (version 1.67). The Log Kow is calculated to be 1.85 and 1.16, respectively.