Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 Nov 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D 93
Principles of method if other than guideline:
The test was performed according the method ASTM D 93
GLP compliance:
no
Type of method:
closed cup
Remarks:
Pensky-Martens closed cup method
Flash point:
144 °C
Atm. press.:
ca. 1 013 hPa

Mean of two test results: 143 °C and 145 °C.

Description of key information

144 °C at ca 1013 hPa (ASTM D93, Pensky-Martens closed cup)

Key value for chemical safety assessment

Additional information