Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

If inhaled: Fresh air.


In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/shower.


In case of eye contact: Rinse out with plenty of water. Remove contact lenses.


If swallowed: Make victim drink water (two glasses at most). Consult doctor if feeling unwell.


 


Most important symptoms and effects, both acute and delayed


Symptoms: We have no description of any toxic symptoms.


 


Indication of any immediate medical attention and special treatment needed


Treatment: No information available.

Fire-fighting measures

Extinguishing media


Suitable extinguishing media: Water, foam, carbon dioxide (CO2), dry powder.


Unsuitable extinguishing media: For this substance no limitations of extinguishing agents are given.


 


Special hazards arising from the substance or mixture


Specific hazards during firefighting: Combustible. Development of hazardous combustion gases or vapors possible in the event of fire.


 


Advice for firefighters


Special protective equipment for firefighters: Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.


Further information: Suppress (knock down) gases/vapors/mists with a water spray jet.


Prevent fire extinguishing water from contaminating surface water or the ground water system.

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Advice for non-emergency personnel: Avoid inhalation of dusts. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.


 


Environmental precautions: Do not flush into surface water or sanitary sewer system.


 


Methods for cleaning up: Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions. Take up with liquid-absorbent material. Dispose of properly. Clean up affected area. Avoid generation of dusts.


 

Handling and storage

Advice on safe handling: Observe label precautions.


Hygiene measures: Immediately change contaminated clothing. Wash hands and face after working with substance.


 


Requirements for storage areas and containers: Store in original container.


Further information on storage conditions: Tightly closed.


Recommended storage temperature: Recommended storage temperature see product label.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering measures


Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.


 


Personal protective equipment


Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled and must meet the specifications of a standard EN/ISO/DIN. The chemical resistance of the protective equipment should be enquired at the respective supplier.


 


Hand protection full contact


Glove material: Nitrile rubber


Glove thickness: 0,11 mm


Break through time: > 480 min


 


Hand protection splash contact


Glove material: Nitrile rubber


Glove thickness: 0,11 mm


Break through time: > 480 min


 


The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374.


 


Protective measures: Protective clothing


Respiratory protection: Required when dusts are generated.


Recommended Filter type: Filter P 1 for solid particles of inert substances.


 


The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.


 


Environmental exposure controls


General advice: Do not flush into surface water or sanitary sewer system.

Stability and reactivity

Chemical stability: The product is chemically stable under standard ambient conditions (room temperature).


Hazardous reactions: Violent reactions possible with: Strong oxidizing agents.


 


Conditions to avoid: No information available.


Materials to avoid: No information available.


 

Disposal considerations

Please dispose according to local legislation