Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 23-September-2016 to 15-December-2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Remarks:
GLP compliant
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Inspection dates: 02 - 04 June 2015 / Date of the certificate: 22 September 2015
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
other: MINIFLASH FLP, Grabner Instruments, Austria
Specific details on test material used for the study:
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL:
- Controlled room temperature (15-25°C, below 70 RH%)
Key result
Flash point:
> 200 °C
Atm. press.:
ca. 101 325 Pa
Remarks on result:
other: no flash point was observed up to 200°C

The test item was measured with two parallel tests.

Interpretation of results:
GHS criteria not met
Conclusions:
No flash point was observed up to 200 °C.
Executive summary:

Determination of the flash point of FLUOROSULFONIC ADDUCT was performed using a MINIFLASH automatic flash point tester with the continuously closed cupelectric arc non equilibrium method according to standardised guidelines (EU Method A.9) under GLP conditions.

No flash point was observed up to 200°C.

Description of key information

No flash point was observed up to 200 °C.

Key value for chemical safety assessment

Additional information

Determination of the flash point of Fluorosulfonic adduct was performed using a MINIFLASH automatic flash point tester with the continuously closed cup – electric arc non equilibrium method according to standardised guidelines (EU Method A.9) under GLP conditions.