Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 May 2008 and 02 June 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not effect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
With the exception of the explosive and oxidising properties predictions the work described was performed in compliance with UK GLP standards (Schedule 1, Good Laboratory Practice Regulations 1999 (SI 1999/3106 as amended by SI 2004/0994)).
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
Lithium naphthalene-2-carboxylate
EC Number:
700-040-5
Cas Number:
674347-28-5
Molecular formula:
C11 H7 Li O2
IUPAC Name:
Lithium naphthalene-2-carboxylate

Results and discussion

Density
Type:
relative density
Density:
1.45 kg/m³
Temp.:
21 °C

Any other information on results incl. tables

Result

               Calibration

The pressure readings (P1 and P2) and the calculated volume for the calibration ball are shown in the following table:

Determination

P1

P2

Volume (cm3)

Certified Volume (cm3)

Tolerance

(cm3)

A

17.356

8.596

56.537

56.6

± 0.5

B

17.101

8.468

56.500

56.6

± 0.5

Sample

The pressure readings, calculated volumes and density values obtained for the test material are shown in the following table:

Determination

P1

P2

Volume (cm3)

Density

(kg/m3)

A

17.627

7.056

12.963

1.46 x 103

B

17.531

7.207

18.935

1.44 x 103

Temperature:                21.0 ± 0.5ºC
Mean density:               1.45 x 103 kg/m3
Relative density:            1.45

Conclusion

The relative density of the test material has been determined to be 1.45 at 21.0 ± 0.5°C.

Applicant's summary and conclusion

Conclusions:
The relative density of the test material has been determined to be 1.45 at 21.0 ± 0.5°C.
Executive summary:

The relative density was determined using a gas comparison pycnometer, Method A3 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).

The relative density of the test material has been determined to be 1.45 at 21.0 ± 0.5°C.