Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2006-10-20
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
ASTM D 7094-04
Deviations:
no
Remarks:
ASTM D 7094-04 gives equal results as ASTM D 93
GLP compliance:
no
Type of method:
closed cup
Remarks:
Pensky Martens
Key result
Flash point:
392 K
Atm. press.:
101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point: 392 K (119 ºC)
Executive summary:

The flash point of the substance was determined by the closed cup method using an instrument-specific cup. The flash point was 392 K (119 °C). Thus, classification as flammable liquid is not warranted.

Description of key information

The flash point of Polyol TD is 392 K (119 °C) (Analytical Chemistry, Perstorp Holding AB, 2009). Thus, classification as flammable liquid is not warranted.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
119 °C

Additional information