Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5th August to 7th September 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies which did not affect the quality of relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of inspection: 13th to the 22nd of October 2008 (GLP certificate is valid for 2 years)

Test material

Constituent 1
Reference substance name:
Pellicer
IUPAC Name:
Pellicer
Details on test material:
Name: Pellicer
Lot No.: 01-09-17
Chemical name: L-Lysine,N2,N6-bis[N-(1-oxododecyl)-L-α(or γ)-glutamyl]-, sodium salt (1;?)
Appearance: White powder
Storage condition: Room temperature (15-25 °C), in the dark and protected from humidity (with desiccant)
Manufacture date: 17 January 2009
Expiry Date: 17 January 2011
Safety precautions: Routine safety and hygienic procedures sufficient to ensure personnel health and safety

Results and discussion

Any other information on results incl. tables

In the preliminary test the test item could be ignited but did not propagate burning. Based on the results of the preliminary test, no main test was performed.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The Pellicer could be ignited but did not propagate burning. Therefore, the substance is considered not to be highly flammable.
Executive summary: