Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14.08.2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Boiling pt.:
403 °C
Atm. press.:
1 013 hPa
Decomposition:
no
Conclusions:
The test item had a mean boiling point at atmospheric pressure (1013.3 hPa) of 403.1 °C.
Executive summary:

A study was conducted according to OECD test guideline 103 and Regulation (EC) No 440/2008 method A.2 to determine the boiling point of the test item using differential scanning calorimetry (DSC 25 - 500 °C). The test item and the reference are heated up from the starting temperature to the final temperature at a constant heating rate in a defined atmosphere (nitrogen). Open crucibles are used as containers for the test item and as empty reference crucible. The quantity of heat absorbed or released is measured and recorded. The test item had a mean boiling point at atmospheric pressure (1013.3 hPa) of 403.1 °C.

Description of key information

A study was conducted according to OECD test guideline 103 and Regulation (EC) No 440/2008 method A.2 to determine the boiling point of the test item using differential scanning calorimetry (DSC 25 - 500 °C). The test item and the reference are heated up from the starting temperature to the final temperature at a constant heating rate in a defined atmosphere (nitrogen). Open crucibles are used as containers for the test item and as empty reference crucible. The quantity of heat absorbed or released is measured and recorded. The test item had a mean boiling point at atmospheric pressure (1013.3 hPa) of 403.1 °C.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
403.1 °C