Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The flash point of the test material has been determined to be 200±2°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
200 °C

Additional information

Test Guidance

EU Method A.9 (Flash-Point)

Method and Material

n aliquot (2 or 4 mL depending on tester) of the test material was transferred to the sample cup of the Setaflash 30000 -0 tester. The sample was heated and allowed to equilibrate at the set temperature. The test flame was introduced into the sample cup for approximately 2.5 seconds by sliding the cup shutter open. Observations were made for ignition of the valour. If no ignition occurred, the temperature was increased and the test flame re-introduced. This was repeated until the lowest reproducible temperature at which a flash occurred, using a fresh sample, was determined.

Result

The flash point of the test material has been determined to be 200±2°C.

Conclusion

In accordance with CLP Regulation (EC) No 127/2008 the test material is not classified as flammable