Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
no
GLP compliance:
no
Specific details on test material used for the study:
Test Item: FAT 92368/Y
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Safety pre-test:


A small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed. The test item showed no signs of ignition.


 


Preliminary screening test:


The test item was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes.

Interpretation of results:
GHS criteria not met
Conclusions:
FAT 92368/Y should be considered as not highly flammable.
Executive summary:

FAT 92368/Y was tested for flammability potential as per EU method A.10. In a safety pretest, small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed but the test item did not show any signs of ignition. Consequently, a screening test was performed. The test item arranged in a pile of 2 cm was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. Hence, FAT 92368/Y should be considered as not highly flammable.

Description of key information

FAT 92368/Y was tested for flammability potential as per EU method A.10. In a safety pretest, small amount of the test item was heated on a magnesia groove with a gas burner. Glowing was observed but the test item did not show any signs of ignition. Consequently, a screening test was performed. The test item arranged in a pile of 2 cm was heated with the flame of a teclu burner. Glowing was observed during heating. No ignition occurred within two minutes. Hence, FAT 92368/Y should be considered as not highly flammable.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification

FAT 92368/Y was found to be not flammable when tested in a flammability study, hence it does not require classification in accordance to the criteria of Regulation (EC) No. 1272/2008.