Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
27 April, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
GLP compliance:
not specified
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
(1R,2R)-1-amino-2-difluoromethyl)-N- (1-methylcyclopropylsulfonyl)cyclo propanecarboxyamide hydrochloride
EC Number:
943-460-6
Cas Number:
1360828-80-3
Molecular formula:
C9H15CIF2N203S
IUPAC Name:
(1R,2R)-1-amino-2-difluoromethyl)-N- (1-methylcyclopropylsulfonyl)cyclo propanecarboxyamide hydrochloride
Test material form:
solid: particulate/powder
Details on test material:
White solid

Results and discussion

Density
Key result
Type:
relative density
Density:
1.442 g/cm³
Temp.:
20 °C
Remarks on result:
other: relative standard deviation of 3 times (RSD%) was 0.7%

Any other information on results incl. tables

The average value of the density of the calibration material aviation kerosene was determined to be 0.7876 g/cm³ at 20 °C.

Applicant's summary and conclusion

Conclusions:
The density of Difluorosulfonamide HCl was measured. The test was done in parallel 3 times. The average value of the 3 testing results was 1.4423 g/cm³ (20 °C). The relative standard deviation of 3 times (RSD%) was 0.7%.
Executive summary:

The average value of the 3 testing results was 1.4423 g/cm³ (20 °C). The relative standard deviation of 3 times (RSD%) was 0.7%.