First-aid measures

If inhaled: If you feel unwell, remove to fresh air immediately. Get medical attention if cough or other symptoms develop.
In case of skin contact: Immediately remove contaminated cloting and shoes. flush skin with large amounts of water, clean off with soap and water. get medical attention if symptoms develop.
In case of eye contact: Immediately flush eyes with plenty of water for several minutes. Part eyelids with fingers to assure complete flushing. check for and remove contact lenses if easily possible. get medical attention if irritation persists.
If swallowed: Do not induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Keep the affected person warm and at rest. Get medical attention immediately.
Protection of first-aiders: Wear appropriate personal protective gloves, protective cloting, eye protection, face protection, etc.
Notes to physician: Treat symptomatically.

Fire-fighting measures

Suitable extinguishing media: Water mist, foam, dry chemical, carbon dioxide (CO2), dry sand.
Unsuitable extinguishing media: None.
Specific hazards during firefighting: Emits toxic fumes under fire conditions.
Special protective equipment for firefighters: Respiratory and eye protection required for fire-fighting personnel. Full protective equipment and self-contained breathing apparatus (SCBA) should be used for all indoor fires and any significant outdoor fires.
Further information: Remove all sources of ignition. Keep unnecessary and unprotected personnel away. Remove containers to safe place if possible. Fight fire from an upwind postion. Keep surrounding areas cool by spraying water.

Accidental release measures

Personal precautions, protective equipment and emergency procedures: Wear appropriate personal protective equipment such as protective gloves, protective clothing, eye protection, face protection, etc. Keep unnecessary and unprotected personnel away. Keep unwind, evacuate downwind. Wear appropriate personal protective equipment as specified. Evacuate immediate area. Warn personnel of health hazard.
Environmental precautions: Do not flush into sewer, river, or any body of water. Do not let this chemical enter the environment. Warn and evacuate the neighborhood as necessary.
Methods and materials: Absorb or cover with dry earth, sand or other non-combustible material and transfer to sealable containers. Large spills: Dike far ahead of liquid spill for later disposal. Stop leak if possible without personal risk. Avoid run-off to sewers or waterways. If a non-aqueous product isleaked into the water, use appropriate absorbent material to collect the product.

Handling and storage

Handling
Technical measures: Avoid contact with eyes, skin and clothing. Avoid ingestion and inhalation. Wear appropriate personal protective equipment. Provide hand and eye wash station near work area. Wash thoroughly after handling. Use only in well-ventilated area. Keep away from heat, sparks, and flame. Use explosion-proof electrical equipment and take precautions against build-up of electrostatic charges as necessary.
Advice on safe handling: Do not handle until all safety precautions have been read and understood. Prevent leak and spill. Avoid vapour formation. Do not drop, shock or drag the container. Avoid contact with eyes, skin and clothing. Avoid inhalation and ingestion. Use only in well-ventilated area or outdoors.
Avoidance of contact: Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat, sparks and flame. Store in a segregated and approved area.
Hygiene measures: Wash hands thoroughly after handling. Do not eat, drink, or smoke when using this product.

Storage
Conditions for safe storage: Store locked up. The floor must be protected from water and impermeable. The inventory location must be fire-resisting. make the roof from non-flammable materials, and do not install the ceiling. Install appropriate facilities for lighting/ ventilating. Materials to avoid: strong exidizers.
Suitable container and packaging materials for safe storage: Use containers approved by local and notional authorities.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering measures: Provide safety shower and eye wash station near work area. use closed system or local exhaust ventilation.

Personal protective equipment
Respiratory protection: respirator with filter or organic vapour.
Hand protection: Protective gloves (oil-resistant).
Eye protection: Safety goggles, eye shield, face shield.
Skin and body protection: Protective suit, safety helmet, safety boots, apron (use oil-resistant materials).

Stability and reactivity

Reactivity: No data available.
Chemical stability: Satbel under normal conditions.
Conditions to avoid: Heat, sunlight.
Incompatible materials: Strong oxidizers.
Hazardeous decomposition products: Sulfur oxides.
Hazardeous reactions: No data available.

Disposal considerations

Waste from residues: In accordance with local and national regulations. Dispose of wastes in an approved waste disposal facility. When outsourcing waste treatment, be sure to notify the treatment company regarding the hazards before outsourcing.
Contaminated packaging: Dispose of contents/ container in accordance with local/regional/national/international regulations. Empty the container completely before disposal.