Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
DIN EN 14522, Method P (Determination of the auto ignition temperature of gases and vapours)
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)

Test material

Constituent 1
Reference substance name:
reaction mass of 4-methoxyphenol and 4-methoxy-cyclohexanone and 4-methoxy-cyclohexanol
EC Number:
947-389-1
Molecular formula:
unspecified
IUPAC Name:
reaction mass of 4-methoxyphenol and 4-methoxy-cyclohexanone and 4-methoxy-cyclohexanol

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
433 °C
Atm. press.:
>= 998 - <= 1 017 hPa

Any other information on results incl. tables

Results

test run no. / lowest temperature leading to autoignition [°C] / quantity of sample [ml] / ignition delay time [sec]

1 / 448 / 0.26 / 10

2 / 440 / 0.08 / 30

3 / 443 / 0.08 / 11

Autoignition temperature (corrected)*: 433 °C

* The corrected auto ignition temperature is calculated by subtracting 1.5% of the lowest experimentally observed auto ignition temperature (given in units of °C) in order to take into account all uncertainties (calibration, temperature measuring system, amount of substance, etc.). This value is then rounded to the next 1 K.

Electrical and non-electrical equipment, which may be in contact with explosive mixtures of the test substance and air, has to be of a temperature class T2 or higher.

Applicant's summary and conclusion