Endpoint:
flash point of flammable liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the flash point is only relevant to liquids and low melting point solids

Description of key information

In accordance with Column 2 of REACH Annex VII, the flash point study is required for liquids and low melting point solids. FAT 36034/W is a solid with a melting point 222 °C. Also thermic decomposition was reported at 313 °C. Hence, the study is considered to be technically not feasible.

Key value for chemical safety assessment

Additional information