Administrative data

First-aid measures

Inhalation: Get medical attention immediately. Move exposed person to fresh air. If it is suspected that fumes are still present, the rescuer should

wear an appropriate mask or self-contained breathing apparatus. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours. In the event of any complaints or symptoms, avoid further exposure.

Ingestion: Get medical attention immediately. Wash out mouth with water. Move exposed person to fresh air. Keep person warm and at rest. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Chemical burns must be treated promptly by a physician. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waisteband.

Skin contact: Get medical attention immediately. Remove contaminated clothing and shoes. Wash the skin immediately with plenty of soap and water; cleaning immediately with polyethyleneglycol 400 and washing subsequently with plenty of soap and water would be more effective. Wash skin immediately with plenty of soap and water even when contact with the product is suspected. Chemical burns must be treated promptly by a physician. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Eye contact: Get medical attention immediately. Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Chemical burns must be treated promptly by a physician.

Notes to physician: Basic aid, decontamination, symptomatic treatment. Treat with a corticoid metered aerosol depending on the amount inhaled. If

appropriate symptoms occur or inhalation of large quantities is suspected, administer cortisone intravenously in addition Medical surveillance for at least 48 hours.

Fire-fighting measures

Suitable extinguishing media: In case of fire, use water spray (fog), foam, dry chemical or CO2.

Unsuitable extinguishing media: Do not use water jet

Hazards from the substance or mixture: Combustible liquid. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion.

Hazardous combustion products: Decomposition products may include the following materials: carbon oxides/ nitrogen oxides/ hydrogen cyanide

Advice for firefighters

Special precautions for firefighters

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fireexposed containers cool. This material is harmful to aquatic organisms. Fire water contaminated with this material must be contained and prevented from being discharged to any waterway, sewer or drain.

Special protective equipment for fire-fighters: Fire-fighters should wear appropriate protective equipment and selfcontained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.

Accidental release measures

Personal precautions, protective equipment and emergency procedures: No action shall be taken involving any personal risk or without suitable training. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapour or mist. Provide adequate ventilation. Put on appropriate personal protective equipment

Environmental precautions: Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers. Inform the relevant authorities if the product has caused environmental pollution (sewers, waterways, soil or air). Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.

Methods and materials for containment and cleaning up

Small spill: Stop leak if without risk. Use spark-proof tools and explosion-proof equipment. Take up with a moist, liquid-binding material (e.g. sand,

sawdust or chemical binder based on hydrated calcium silicate) and treat carefully with diluted ammonia solution. Do not firmly seal waste

containers (risk of CO2 generation!). Once the reaction is fully complete, pass on to disposal facilities. Dispose of via a licensed waste disposal contractor. Contaminated absorbent material may pose the same hazard as the spilt product.

Large spill: Stop leak if without risk. Prevent entry into sewers, water courses, basements or confined areas. Use spark-proof tools and explosionproof equipment. Collect spillage. Absorb with an inert material and place in an appropriate waste disposal container. Do not firmly seal waste containers (risk of CO2 generation!). Dispose of via a licensed waste disposal contractor. Carefully decompose residues with an aqueous ammonia solution.

Handling and storage

This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 17(3) for on-site isolated intermediates and, in case the substance is transported to other sites for further processing, the substance should be handled at these sites under the Strictly Controlled Conditions as specified in REACH regulation Article 18(4). Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each Manufacturing site. Written confirmation of application of Strictly Controlled Conditions has been received from affected Distributor and Downstream Manufacturer/User of the Registrants intermediate.

Precautions for safe handling

Put on appropriate personal protective equipment. Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Persons with a history of asthma, allergies or chronic or recurrent respiratory disease should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not breathe vapour or mist. Do not ingest. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a

compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use non-sparking tools. Take precautionary measures against electrostatic discharges. To avoid fire or explosion, dissipate static electricity during transfer by earthing and bonding containers and equipment before transferring material. Empty containers retain product residue and can be hazardous.

Conditions for safe storage, including any incompatibilities

Store in accordance with local regulations. Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see section 10) and food and drink. Eliminate all ignition sources. Separate from oxidizing materials. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled  containers. Use appropriate containment to avoid environmental contamination.

Remarks: Ensure effective ventilation. Make sure all pipelines, tanks and equipment are leakproof. Vent waste air only via suitable separators or scrubbers.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN3390
Shipping information
Proper shipping name and description:
Toxic by inhalation liquid, corrosive, N.O.S.
Chemical name:
p-tolyl isocyanate
Language:
English
Labels:
Skull and cross bones
Corrosive
Fish and tree
Special provisions / remarks
Special provisions:
Hazard identification number 668

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN3390
Shipping information
Proper shipping name and description:
Toxic by inhalation liquid, corrosive, N.O.S.
Chemical name:
p-tolyl isocyanate
Language:
English
Labels:
Skull and cross bones
Corrosive
Fish and tree
Special provisions / remarks
Remarks:
Hazard identification number 668

Marine transport (UN RTDG/IMDG)

UN number:
UN3390
Shipping information
Proper shipping name and description:
Toxic by inhalation liquid, corrosive, N.O.S.
Chemical name:
p-tolyl isocyanate
Labels:
Skull and cross bones
Corrosive
Fish and tree
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
-
Shipping information
Proper shipping name and description:
-
Chemical name:
-
Labels:
-
Special provisions / remarks
Remarks:
Forbidden

Additional transport information

Additional information
Special provisions / remarks / other:
Highly toxic.
Corrosive.
Combustible.
Flash point (Closed cup): 66°C
Pungent smelling.
Keep dry.
Keep away from foodstuffs, acids and alkalis.

Exposure controls / personal protection

This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 17(3) for on-site isolated intermediates and, in case the substance is transported to other sites for further processing, the substance should be handled at these sites under the Strictly Controlled Conditions as specified in REACH regulation Article 18(4). Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each Manufacturing site. Written confirmation of application of Strictly Controlled Conditions has been received from affected Distributor and Downstream Manufacturer/User of the Registrants intermediate.

Technical measures: Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment

Respiratory protection: Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Recommended: Full mask with type ABEK filter if product forms vapours . If larger quantities escape, self-contained breating

Hand protection:  Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical

products if a risk assessment indicates this is necessary. After contamination with product change the gloves immediately and dispose of them according to relevant national and local regulations Recommended: (< 1 hour) Polyvinyl chloride - PVC, Polychloroprene - CR, Fluorinated rubber - FKM

apparatus must be used.

Eye protection: Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. Recommended: Tightly fitting safety goggles.

Skin protection: Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should

be approved by a specialist before handling this product. Recommended: chemical-resistant protective suit

Hygiene measures: Wash hands, forearms and face thoroughly after handling chemical products, before eating, smoking and using the lavatory and at the end of the working period. Appropriate techniques should be used to remove potentially contaminated clothing. Wash contaminated

clothing before reusing. Ensure that eyewash stations and safety showers are close to the workstation location.

Environmental exposure controls

Technical measures : Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of

environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Stability and reactivity

Reactivity: No specific test data related to reactivity available for this product or its ingredients.

Chemical stability: Hazardous polymerization may occur under certain conditions of storage or use.

Possibility of hazardous reactions: Hazardous reactions or instability may occur under certain conditions of storage or use.

Conditions to avoid: Reactive with water, alcohols, acids, alkalis, and amines. With water (in a closed container), pressure will increase and create a risk of bursting. Do not pressurise, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.

Incompatible materials: Not applicable.

Hazardous decomposition products: Under normal conditions of storage and use, hazardous decomposition products should not be produced.

Disposal considerations

Product

Methode of disposal: Examine possibilities for re-utilisation. Product residues and uncleaned empty containers should be packaged, sealed, labelled, and disposed of or recycled according to relevant national and local regulations. Where large quantities are concerned, consult the supplier. When uncleaned empty containers are passed on, the recipient must be warned of any possible hazard that may be caused by residues. For disposal within the EC, the appropriate code according to the European Waste List (EWL) should be used. It is among the tasks of the polluter to assign the waste to waste codes specific to industrial sectors and processes according to the European Waste List (EWL).

Hazardous wate: The classification of the product may meet the criteria for a hazardous waste.

Packaging

Methods of disposal: The generation of waste should be avoided or minimised wherever possible. Waste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible.

Special precautions: This material and its container must be disposed of in a safe way.  Care should be taken when handling emptied containers that have not been cleaned or rinsed out. Empty containers or liners may retain some product residues. Vapor from product residues may create a highly flammable or explosive atmosphere inside the container. Do not cut, weld or grind used containers unless they have been cleaned thoroughly internally. Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.