Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Contact with:
powdered cellulose
Duration of test (contact time):
ca. 14 s
Sample tested:
test mixture (not specified)
Parameter:
mean pressure rise time
Result:
ca. 14 s
Sample tested:
reference mixture (not specified)
Parameter:
other: maximum burning rate
Result:
ca. 2.3 s
Interpretation of results:
GHS criteria not met
Conclusions:
In a GLP-study according to EU Method A.21, the registered substance did not have any oxidising properties.
Executive summary:

In the test for oxidising properties of liquids, the pressure increase of a mixture of test item with cellulose 1:1 was much slower than the pressure increase of the reference mixture (nitric acid 65 % and cellulose 1:1).
Therefore, the test item CARDOLITE NC-513 is classified to be not oxidising.

Description of key information

oxidising properties (determined using EU Method A.21; GLP): no

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

In a test for oxidising properties of liquids, the pressure increase of a mixture of test item with cellulose (1:1) was much slower than the pressure increase of the reference mixture (nitric acid 65 % and cellulose 1:1).
Therefore, the test item CARDOLITE NC-513 is classified to be not oxidising.

Justification for classification or non-classification

Based on the results of a study according to EU Method A.21, the registered substance does not need to be classified regarding oxidising properties.