Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 211-932-4 | CAS number: 713-95-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Endpoint summary
Administrative data
Description of key information
Bioaccumulation: aquatic / sediment
BCFBAF model of Estimation Programs Interface was used to predict the bioconcentration factor (BCF) of test chemical (2018). The bioconcentration factor (BCF) of test chemical was estimated to be 102.1 L/kg whole body w.w (at 25 deg C) which does not exceed the bio concentration threshold of 2000, indicating that the test chemical is not expected to bioaccumulate in the food chain.
Additional information
Bioaccumulation: aquatic / sediment
Various predicted data of the test chemical and supporting weight of evidence studies for its structurally similar read across substance were reviewed for the bioaccumulation end point which are summarized as below:
In aprediction done using theBCFBAF Programof Estimation Programs Interface was used to predict the bioconcentration factor (BCF) of test chemical. The bioconcentration factor (BCF) of test chemical was estimated to be 102.1 L/kg whole body w.w (at 25 deg C).
In an another prediction done by using Bio-concentration Factor (v12.1.0.50374) moduleACD (Advanced Chemistry Development)/I-Lab predictive module, 2017), theBio-concentration Factor of the test chemical was estimated to be 260 at pH range 1-14, respectively.
SciFinder database (American Chemical Society (ACS), 2017) was used for predicting the bioconcentration factor (BCF) of test chemical. The bioconcentration factor (BCF) of test chemical was estimated to be 264 at pH range 1-10 respectively (at 25 deg C).
From CompTox Chemistry Dashboard using OPERA (OPEn (quantitative) structure-activity Relationship Application) V1.02 model in which calculation based on PaDEL descriptors (calculate molecular descriptors and fingerprints of chemical), the bioaccumulation i.e BCF for test chemical was estimated to be 10.8 dimensionless . The predicted BCF result based on the 5 OECD principles.
In a supporting weight of evidence study from authoritative database (HSDB, 2017) for the test chemical, the bioaccumulation experiment was conducted in fish for estimating the BCF (bioaccumulation factor) value of test chemical. The bioaccumulation factor (BCF) value was calculated using an estimated log Kow of 2.83 and a regression derived equation. The BCF (bioaccumulation factor) value test substance in fish was determined to be 34 dimensionless.
For the test chemical, the bioaccumulation study was conducted for estimating the BCF (bioaccumulation factor) value of test chemical (authoritative database, 2017). The bioaccumulation factor (BCF) value was calculated using an estimated log Kow of 3.32 and a regression derived equation. The BCF (bioaccumulation factor) value test substance was determined to be 72 dimensionless.
On the basis of above results for test chemical, it can be concluded that the BCF value of test chemical was evaluated to be ranges from 10.8 to 264, respectively,which does not exceed the bioconcentration threshold of 2000, indicating that the test chemical is not expected to bioaccumulate in the food chain.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.