Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1999
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The study report did not specify which guideline was followed or whether the study was conducted in accord with GLP guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1999
Report date:
1999

Materials and methods

Test guideline
Qualifier:
no guideline followed
Deviations:
not applicable
Principles of method if other than guideline:
Method utilizes an automated rotational viscometer
GLP compliance:
not specified
Type of method:
rotational viscometer (dynamic)

Test material

Constituent 1
Reference substance name:
PBSF
IUPAC Name:
PBSF
Details on test material:
- Name of test material (as cited in study report): F-15136

Results and discussion

Viscosity
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1.48

Any other information on results incl. tables

The viscosity at 0, 10, 20, and 25 °C was measured directly (Table 1)

Table 1
Temp, °C Viscosity, cP
25.0 1.44
20.0 1.48
10.0 1.60
0.0 1.66

Applicant's summary and conclusion

Conclusions:
The viscosity of PBSF is 1.48 mPa s at 20.0 °C
Executive summary:

The viscosity of PBSF was measured using a Brookfield LVTDT-II+ Viscometer with the ultra low (UL) adapter at various specified temperatures. The temperature was controlled through a refrigerated temperature bath/circulator connected to the sample cup jacket. Although automated viscometry is permitted by OECD TG 114, it is unknown whether this study follows an OECD, ISO or ASTM guideline. Therefore this study is classified as reliable with restrictions.