Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
09 Mar 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
other: ASTM D92
GLP compliance:
no
Type of method:
open cup
Remarks:
Cleveland Open Cup
Flash point:
120 °C
Atm. press.:
ca. 1 013 hPa

Pressure was not reported. Data is estimated, because the test was conducted under ambient condition using an open cup system.

Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09 Mar 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
equilibrium method closed cup
Remarks:
Pensky-Martens Closed Cup
Flash point:
128.5 °C
Atm. press.:
998 hPa

Description of key information

128.5 °C at 998 hPa (closed cup, ASTM D93)

Key value for chemical safety assessment

Additional information

A second flash point determined with an open cup method of 120 °C is supporting.