Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Oct. 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Fully documented study run according to international guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Qualifier:
according to guideline
Guideline:
other: Standard VDI 2263
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
counted distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
(3R,4S,5R)-3,4,5-trihydroxycyclohex-1-enecarboxylic acid
EC Number:
205-334-2
EC Name:
(3R,4S,5R)-3,4,5-trihydroxycyclohex-1-enecarboxylic acid
Cas Number:
138-59-0
Molecular formula:
C7H10O5
IUPAC Name:
(3R,4S,5R)-3,4,5-trihydroxycyclohex-1-enecarboxylic acid
Details on test material:
Samples are from Batch: 1329Ro37, Lot: 0700791872.

Results and discussion

Particle sizeopen allclose all
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Percentile:
D10
Mean:
1.21 µm
Remarks on result:
other: St.dev. not indicated
Percentile:
D50
Mean:
6.52 µm
Remarks on result:
other: St.dev. not indicated
Percentile:
D90
Mean:
13.3 µm
Remarks on result:
other: St.dev. not indicated

Applicant's summary and conclusion

Conclusions:
Fifty percent by volume of the particles have a diameter of more than 6.52 micrometer.
Executive summary:

The particle size distribution was determined by laser diffraction method with LS 13 320 particle size analyzer from Beckman Coulter.

Fifty percent by volume of the particles have a diameter of more than 6.52 micrometer.