Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 205-232-8 | CAS number: 136-23-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to aquatic algae and cyanobacteria
Administrative data
Link to relevant study record(s)
- Endpoint:
- effects on growth of green algae
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: read-across from a comparable to guideline and with acceptable restrictions study
- Justification for type of information:
- The long-term toxicity of zinc bis(dibutyldithiocarbamate) to aquatic invertebrates is based on read-across from the structural analogue zinc bis(diethyldithiocarbamate).
- Reason / purpose for cross-reference:
- read-across source
- Key result
- Duration:
- 96 h
- Dose descriptor:
- EC50
- Effect conc.:
- 1.1 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- growth rate
- Endpoint:
- toxicity to aquatic algae and cyanobacteria
- Type of information:
- migrated information: read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study with acceptable restrictions
- Remarks:
- OECD guideline study, published in lierature, minor restrictions in reporting, but otherwise adequate for assessment
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 201 (Alga, Growth Inhibition Test)
- GLP compliance:
- no
- Analytical monitoring:
- no
- Vehicle:
- no
- Test organisms (species):
- Chlorella pyrenoidosa
- Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 96 h
- Test temperature:
- 20± 1 °C
- Details on test conditions:
- TEST SYSTEM
- Test vessel: Erlenmeyer flasks
- Type (delete if not applicable): closed
- Material, size, headspace, fill volume: 200 ml
- Aeration: placed on a mechanical shaker
- Initial cells density: approximately 10E8 cells .1E-1 (100 ml)
- The tests were carried out in triplicate.
TEST MEDIUM / WATER PARAMETERS
- The composition of the medium used is given elsewhere (Van Leeuwen and Maas, 1985).
OTHER TEST CONDITIONS
- Light intensity and quality: placed under fluorescent light (7.5 W/m²) - Reference substance (positive control):
- not specified
- Duration:
- 96 h
- Dose descriptor:
- EC50
- Effect conc.:
- 1.1 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- growth rate
Referenceopen allclose all
Description of key information
The 96-h ErC50 of 1.1 mg/L in Chlorella pyrenoidosa will be used in the assessment.
Key value for chemical safety assessment
- EC50 for freshwater algae:
- 1.1 mg/L
Additional information
No growth inhibition tests with algae are available for zinc bis(dibutyldithiocarbamate). The results from the structural analogue zinc diethyldithiocarbamate are used (for details see Reporting Format as attached to the respective IUCLID entry and CSR Appendix A.1). A 96-h ErC50 value of 1.1 mg/L in Chlorella pyrenoidosa from a semi-static non-GLP, OECD 201 guideline study without analytical monitoring (van Leeuwen et al., 1985b) is used in the assessment.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.