Registration Dossier

Administrative data

Endpoint:
relative density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 May 2008 and 02 June 2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted to GLP and in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not effect the quality of the relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.3 (Relative Density)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
With the exception of the explosive and oxidising properties predictions the work described was performed in compliance with UK GLP standards (Schedule 1, Good Laboratory Practice Regulations 1999 (SI 1999/3106 as amended by SI 2004/0994)).
Type of method:
pycnometer method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Density
Type:
relative density
Density:
1.45 kg/m³
Temp.:
21 °C

Any other information on results incl. tables

Result

               Calibration

The pressure readings (P1 and P2) and the calculated volume for the calibration ball are shown in the following table:

Determination

P1

P2

Volume (cm3)

Certified Volume (cm3)

Tolerance

(cm3)

A

17.356

8.596

56.537

56.6

± 0.5

B

17.101

8.468

56.500

56.6

± 0.5

Sample

The pressure readings, calculated volumes and density values obtained for the test material are shown in the following table:

Determination

P1

P2

Volume (cm3)

Density

(kg/m3)

A

17.627

7.056

12.963

1.46 x 103

B

17.531

7.207

18.935

1.44 x 103

Temperature:                21.0 ± 0.5ºC
Mean density:               1.45 x 103 kg/m3
Relative density:            1.45

Conclusion

The relative density of the test material has been determined to be 1.45 at 21.0 ± 0.5°C.

Applicant's summary and conclusion

Conclusions:
The relative density of the test material has been determined to be 1.45 at 21.0 ± 0.5°C.
Executive summary:

The relative density was determined using a gas comparison pycnometer, Method A3 of Commission Directive 92/69/EEC (which constitutes Annex V of Council Directive 67/548/EEC).