Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
acute toxicity: inhalation
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because exposure of humans via inhalation is not likely taking into account the vapour pressure of the substance and/or the possibility of exposure to aerosols, particles or droplets of an inhalable size
other:
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-07-29
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
other: ASTM-D 2879
GLP compliance:
no
Type of method:
isoteniscope
Temp.:
25 °C
Vapour pressure:
< 0.001 hPa

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion