flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Flammability test performed based on national standard VDI2263/Clariant internal method

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: VDI- Richtlinie 2263 (national standard)
Principles of method if other than guideline:
A sample in a pile form is ignited using a flame and an electrically heated Platinum wire and the burning behaviour was observed.
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
4'-ethoxy-3-hydroxy-2-naphthanilide
EC Number:
225-200-7
EC Name:
4'-ethoxy-3-hydroxy-2-naphthanilide
Cas Number:
4711-68-6
Molecular formula:
C19H17NO3
IUPAC Name:
N-(4-ethoxyphenyl)-3-hydroxy-2-naphthamide

Results and discussion

Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Remarks on result:
other: Combustibility Index: 2; no burning when contacted by a flame. When using a heated platinum wire a short local flame up was observed which disappeared when the flame was removed. No selfdriven propagation was observed. Melting of the substance observed
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

No selfdriven propagation of burning when contacted by a flame or heated platinum wire. Therefore the measurement of the burning rate is technically not feasible and needed

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
No classification as flammable solid