Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
14-Jul-2015
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
other: DIN 51562
GLP compliance:
no
Type of method:
other: Ubbelohde viscosimeter
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.88

Results

Test: 1

Capillary tube: 0a

Correction factor 0.009665

Measured time [s]

Mean value (s)

195

195

195

195

195

195

 

Calculation

Viscosity (mm2/s)

time (mean value) x correction factor = viscosity

1.8847

 

Test: 2

Capillary tube: I

Correction factor 0.009678

Measured time [s]

Mean value (s)

193

193

193

194

193

193

 

Calculation

Viscosity (mm2/s)

time (mean value) x correction factor = viscosity

1.8679

 

Final result

Viscosity at 20 °C (mm2/s) = 1.88

Conclusions:
A dynamic viscosity of 1.88 mm²/s at 20 °C was determined in a reliable study conducted according to an appropriate test protocol. It was not compliant with GLP.

Description of key information

1.88 mm²/s at 20°C (DIN 56152, static)

Key value for chemical safety assessment

Viscosity:
1.88 mm²/s (static)
at the temperature of:
20 °C

Additional information