Key study: EU method. GLP study.
After applying the flame of burner, the sample ignite but only in the flame zone.The flame is not spread to the rest of the train. Burning stops after about 30-40s. The test substance is not highly flammable in accordance with test A.10. criteria.
Data waiving: There are no functional groups within the test item molecule that could cause pyrophoricity or flammability in contact with water, basis: "Guidance on information requirements and chemical safety assessment", Chapter R.7a: Endpoint specific guidance.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Key study: EU method. GLP study.

After applying the flame of burner, the sample ignite but only in the flame zone.The flame is not spread to the rest of the train. Burning stops after about 30-40s. The test substance is not highly flammable in accordance with test A.10. criteria.

Data waiving: There are no functional groups within the test item molecule that could cause pyrophoricity or flammability in contact with water, basis: "Guidance on information requirements and chemical safety assessment", Chapter R.7a: Endpoint specific guidance.

Justification for classification or non-classification

Based on the available results, the substance is non flammable.