Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Skin irritation / corrosion

Currently viewing:

Administrative data

Endpoint:
skin irritation / corrosion
Remarks:
other: details not available
Type of information:
other: published data
Adequacy of study:
weight of evidence
Reliability:
4 (not assignable)

Data source

Reference
Reference Type:
other: safety data sheet
Title:
Safety data sheet of 4-Amino-1-naphthalenesulfonic acid sodium salt hydrate
Author:
Sigma Aldrich
Year:
2012
Bibliographic source:
published data

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other:
Principles of method if other than guideline:
Details not available
GLP compliance:
not specified

Test material

Constituent 1
Chemical structure
Reference substance name:
Sodium 4-aminonaphthalene-1-sulphonate
EC Number:
204-975-5
EC Name:
Sodium 4-aminonaphthalene-1-sulphonate
Cas Number:
130-13-2
Molecular formula:
C10H9NO3S.Na
IUPAC Name:
sodium 4-aminonaphthalene-1-sulfonate
Test material form:
solid: crystalline
Details on test material:
CAS number: 130-13-2
Chemical Name: sodium 4-aminonaphthalene-1-sulphonate
Molecular formula: C10H9NO3S.Na

Results and discussion

In vivo

Results
Remarks on result:
other: Irritating to the skin

Applicant's summary and conclusion

Interpretation of results:
irritating
Remarks:
Migrated information Criteria used for interpretation of results: EU
Conclusions:
The chemical sodium 4-aminonaphthalene-1-sulphonate is found to be irritating to the skin as per the data published in the SDS of Sigma Aldrich
Executive summary: