Registration Dossier

Classification & Labelling & PBT assessment

GHS

Currently viewing:

General Information

Implementation:
EU
Remarks:

Legal classification as laid out in regulation (EC) 1272/2008, Annex VI, Index No. 051-001-00-8. However, newly generated substance specific hazard data do not support the harmonised classification and labelling for this antimony compound as stated in Annex VI of regulation (EC) 1272/2008. Therefore, an alternative proposal for the classification and labelling of antimony trichloride (representative sample) is provided as well.

Related composition

Related composition:
Composition 2
Composition 4

Classificationopen allclose all

Explosives
Reason for no classification:
data conclusive but not sufficient for classification
Flammable gases and chemically unstable gases
Reason for no classification:
data conclusive but not sufficient for classification
Aerosols
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising gases
Reason for no classification:
data conclusive but not sufficient for classification
Gases under pressure
Reason for no classification:
data conclusive but not sufficient for classification
Flammable liquids
Reason for no classification:
data conclusive but not sufficient for classification
Flammable solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-reactive substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric liquids
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-heating substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Substances and mixtures which in contact with water emit flammable gases
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising liquids
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising solids
Reason for no classification:
data conclusive but not sufficient for classification
Organic peroxides
Reason for no classification:
data conclusive but not sufficient for classification
Corrosive to metals
Reason for no classification:
data conclusive but not sufficient for classification
Desensitized explosives
Reason for no classification:
data lacking
Acute toxicity - oral
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - dermal
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - inhalation
Reason for no classification:
data conclusive but not sufficient for classification
Skin corrosion / irritation
Hazard category:
Skin Corr. 1B
Hazard statement:
H314: Causes severe skin burns and eye damage.
Serious eye damage / eye irritation
Reason for no classification:
data conclusive but not sufficient for classification
Respiratory sensitisation
Reason for no classification:
data conclusive but not sufficient for classification
Skin sensitisation
Reason for no classification:
data conclusive but not sufficient for classification
Aspiration hazard
Reason for no classification:
data conclusive but not sufficient for classification
Reproductive toxicity
Reason for no classification:
data conclusive but not sufficient for classification
Effects on or via lactation
Reason for no classification:
data conclusive but not sufficient for classification
Germ cell mutagenicity
Reason for no classification:
data conclusive but not sufficient for classification
Carcinogenicity
Reason for no classification:
data conclusive but not sufficient for classification
1. Specific target organ toxicity - single
Reason for no classification:
data conclusive but not sufficient for classification
1. Specific target organ toxicity - repeated
Reason for no classification:
data conclusive but not sufficient for classification
1.
Concentration range (%):
>= 5
Hazard categories:
STOT SE3 / H335
Hazardous to the aquatic environment (acute / short-term)
Reason for no classification:
data conclusive but not sufficient for classification
Hazardous to the aquatic environment (long-term)
Hazard category:
Aquatic Chronic 2
Hazard statement:
H411: Toxic to aquatic life with long lasting effects.
Hazardous to the ozone layer
Reason for no classification:
data conclusive but not sufficient for classification

Labelling

Signal word:
Danger

Hazard pictogram

GHS05: corrosion
GHS09: environment
GHS07: exclamation mark

Hazard statements

H314: Causes severe skin burns and eye damage.
H411: Toxic to aquatic life with long lasting effects.
H335: May cause respiratory irritation.
Applicable for mixtures that contain at least 5% of Antimony trichloride

Precautionary statements

P260: Do not breathe dust/fume/gas/mist/vapours/spray.
P261: Avoid breathing dust/fume/gas/mist/vapours/spray.
P271: Use only outdoors or in a well-ventilated area.
P273: Avoid release to the environment.
P280: Wear protective gloves/protective clothing/eye protection/face protection/hearing protection/...
P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304+P340: IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P310: Immediately call a POISON CENTER/doctor/…
P312: Call a POISON CENTER/doctor/.../if you feel unwell.
P391: Collect spillage.
P403+P233: Store in a well-ventilated place. Keep container tightly closed.
P405: Store locked up.
P501: Dispose of contents/container to ...
Dispose of in a manner consistent with federal, state, and local regulations.

Notes