Endpoint:
oxidising properties
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23.07.2012 to 07.08.2012
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other:
Principles of method if other than guideline:
Redox titrations are based on a reduction-oxidation reaction between an oxidizing agent and a reducing agent. A potentiometer or a redox indicator is usually used to determine the endpoint of the titration. In permanganometry a slight faint persisting pink color signals the endpoint of the titration because of the color of the excess oxidizing agent potassium permanganate
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
4-fluoroaniline
EC Number:
206-735-5
EC Name:
4-fluoroaniline
Cas Number:
371-40-4
Molecular formula:
C6H6FN
IUPAC Name:
4-fluoroaniline
Details on test material:
- Name of test material: 4-fluoroaniline
- Molecular formula: C6H6FN
- Molecular weight: 111.12
- Substance type: Organic
- Physical state: Liquid

Results and discussion

Test results (Oxidising liquids)
Sample tested:
other: not specified (migrated information) mL or mg of KMnO4
Parameter:
other: mL or mg of KMnO4
Result:
172.4 other: mg/100g test substance
Test results (Oxidising solids)
Sample tested:
other: not specified (migrated information) mL or mg of KMnO4
Parameter:
other: mL or mg of KMnO4
Result:
172.4 other: mg/100g test substance

Applicant's summary and conclusion

Interpretation of results:
other: oxidising
Remarks:
Migrated information
Conclusions:
4-fluoroaniline was found to be oxidising with the redox titration yielding an end point of 172.4 ml KMnO4 per 100g of analyte 4-fluoroaniline.
Executive summary: