Endpoint:
phototransformation in air
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
other: Prediction model
Title:
Phototransformation in air by Environmental Science Center’s PBT profiler
Author:
Environmental Science Center
Year:
2010
Bibliographic source:
PBT profiler, Office of Chemical Safety and Pollution Prevention , U.S. Environmental Protection Agency; version 1.301

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Modelling datatbase
Principles of method if other than guideline:
Estimation database
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
4-fluoroaniline
EC Number:
206-735-5
EC Name:
4-fluoroaniline
Cas Number:
371-40-4
Molecular formula:
C6H6FN
IUPAC Name:
4-fluoroaniline
Details on test material:
- Name of test material: 4-fluoroaniline
- Molecular formula: C6H6FN
- Molecular weight: 111.12
- Substance type: Organic
- Physical state: Liquid

Study design

Light source:
not specified
Duration of test at given test condition
Duration:
41 d
Temp.:
25 °C

Results and discussion

% Degradation
% Degr.:
50
Sampling time:
0.46 d
Test condition:
Other details not available
Degradation rate constant
Reaction with:
OH radicals
Rate constant:
0 cm³ molecule-1 s-1
Transformation products:
not specified

Applicant's summary and conclusion

Conclusions:
The half life of 4-fluoroaniline in air is estimated to be 0.46 days. 4-fluoroaniline shows very less dispersion into air under normal conditions. It has 1% partitioning in air.
Executive summary:

The atmospheric oxidation half-life of 4-fluoroaniline was estimated using the level III multimedia model. It was estimated that the substance is non persistent in air medium as the half life period of 4-fluoroaniline in air is only 0.46 days. Also, the percentage of 4-fluoroaniline in air medium is 1%. 4-fluoroaniline shows very less dispersion into air under normal conditions.