Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 205-153-9 | CAS number: 134-71-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Toxicity to microorganisms
Administrative data
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: Guideline study in compliance with GLP-criteria.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 003
- Report date:
- 2003
Materials and methods
Test guideline
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- GLP compliance:
- yes (incl. QA statement)
Test material
- Reference substance name:
- (R*,S*)-(±)-α-[1-(methylamino)ethyl]benzyl alcohol hydrochloride
- EC Number:
- 205-153-9
- EC Name:
- (R*,S*)-(±)-α-[1-(methylamino)ethyl]benzyl alcohol hydrochloride
- Cas Number:
- 134-71-4
- Molecular formula:
- C10 H15 N O .Cl H
- IUPAC Name:
- (1-hydroxy-1-phenylpropan-2-yl)(methyl)azanium chloride
- Details on test material:
- - Name of test material (as cited in study report): DL-Ephedrin-Hydrochlorid
- Physical state: solid, crystalline, white
- Homogeneity: homogeneous
- Stability under test conditions: stable
- STorage conditions: ambient (RT)
Constituent 1
Sampling and analysis
- Analytical monitoring:
- no
Test solutions
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION:
A stock solution of 2000 mg/L was prepared. The test concentrations were made by diluting the stock solution with deionized water.
Test organisms
- Test organisms (species):
- activated sludge
- Details on inoculum:
- Activated sludge from laboratory wastewater plant treating municipal sewage. The inoculum was washed, brought to a concentration of 5 g/L dry substance and aerated during the night. 50 mL were added to a total volume of 250 mL to obtain a concentration of 1 g/L dry substance in the test.
Study design
- Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 30 min
Test conditions
- Test temperature:
- 20 ±2 °C
- pH:
- 5.1 -7.6
- Dissolved oxygen:
- - Oxygen concentration during aeration: > 2.5 mg/L
- Oxygen concentration immediately before measurement: > 6.5 mg/L - Nominal and measured concentrations:
- - Nominal concentrations: 0 (control), 248, 496, 1000 mg/L.
- Details on test conditions:
- TEST SYSTEM:
- Test vessels: Erlenmeyer-vessel (nominal volume 250 mL)
- Test volume: 250 mL
- Synthetic medium: 8 mL/vessel, 100-fold concentrated OECD medium
TEST MEDIUM / WATER PARAMETERS
- Culture medium different from test medium: yes
- Test medium: 8 ml/vessel 100-fold concentrated OECD medium - Reference substance (positive control):
- yes
- Remarks:
- 3,5 dichlorophenol
Results and discussion
Effect concentrationsopen allclose all
- Duration:
- 30 min
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- growth inhibition
- Duration:
- 30 min
- Dose descriptor:
- other: EC20
- Effect conc.:
- ca. 500 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- growth inhibition
- Duration:
- 30 min
- Dose descriptor:
- EC10
- Effect conc.:
- ca. 380 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Details on results:
- No EC10 value was reported. It was determined visually by the reviewer from the graphical presentation of data.
With an EC20 value of >100 mg/L, disturbances in the biodegradation process of activated sludge are not to be expected if the test substance is correctly introduced into wastewater treatment plants at low concentrations. - Results with reference substance (positive control):
- EC20: ca. 1.5 mg/L
EC50: ca. 8.3 mg/L
Applicant's summary and conclusion
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.