Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
25.10.2012 to 06.11.2012
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other:
Principles of method if other than guideline:
Measurement of relative amounts of particles present, sorted according to size
GLP compliance:
no
Type of distribution:
counted distribution

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2,2-trifluoroacetamide
EC Number:
206-559-9
EC Name:
2,2,2-trifluoroacetamide
Cas Number:
354-38-1
Molecular formula:
C2H2F3NO
IUPAC Name:
2,2,2-trifluoroacetamide
Test material form:
solid: crystalline
Details on test material:
- Name of test material : 2,2,2-trifluoroacetamide
- Molecular formula : C2H2F3NO
- Substance type: Organic
- Physical state: Solid

Results and discussion

Particle size
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
Particle size distribution at different passagesopen allclose all
No.:
#1
Size:
600 µm
Distribution:
44.03 %
No.:
#2
Size:
500 µm
Distribution:
4.88 %
No.:
#3
Size:
300 µm
Distribution:
39.57 %
No.:
#4
Size:
150 µm
Distribution:
11.41 %

Applicant's summary and conclusion

Conclusions:
The particle size distribution (granulometry) of 2,2,2-trifluoroacetamide by the sieve analysis method was found to be in the range of 150 micrometer to 600 micrometer. Majority of the particles were found to be in the size of 600 (44.03%) micrometer in size.
Executive summary:

The particle size distribution (granulometry) of 2,2,2-trifluoroacetamide by the sieve analysis method was found to be in the range of 150 micrometer to 600 micrometer. Majority of the particles were found to be in the size of 600 (44.03%) micrometer in size.