Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2013-05-10
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidance followed, no GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Type of method:
non-equilibrium method closed cup

Test material

Constituent 1
Reference substance name:
phthalic anhydride, distillation residues
EC Number:
932-014-6
IUPAC Name:
phthalic anhydride, distillation residues
Test material form:
solid: compact
Details on test material:
- Substance type: organic
- Physical state: solid

Results and discussion

Flash point
Flash point:
ca. 105.6 °C
Atm. press.:
ca. 101 325 Pa

Any other information on results incl. tables

Correction of flash point: YES according Tcorr. = Tatm.+ 0.25 . (101.3 - patm.)

Standard deviation: 0.7 °C

Average flash point: 105.6 ± 0.7 °C at 101.325 kPa

Applicant's summary and conclusion