Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The test was performed according to an industry accepted method.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM D445-97 Standard Test Method for Kinematic Viscosity of Transparent and Opaque liquids (the Calculation of Dynamic Viscosity)
Deviations:
no
GLP compliance:
no
Type of method:
capillary viscometer (static)

Test material

Results and discussion

Viscosityopen allclose all
Temp.:
other: 100.0°C
Parameter:
other: cSt
Value:
48.07
Temp.:
40°C
Parameter:
other: cSt
Value:
2 766

Applicant's summary and conclusion

Conclusions:
The visocity of the test material at 100 C was determined to be 48.07cSt and 2766 cSt at 40 C
Executive summary:

The viscosity of the test substance was determined according to ASTM D445-97 Standard Test Method for Kinematic Viscosity of Transparent and Opaque liquids (the Calculation of Dynamic Viscosity). Viscosities were measured at two temperatures:

Viscosity at 100 deg. C is 48.07 cSt

Viscosity at 40 deg. C is 2766 cSt