Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2019-01-28 to 2019-03-12
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
no guideline followed
Principles of method if other than guideline:
Grewer-oven screening test.
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Key result
Remarks on result:
no self-ignition observed up to the melting point
Conclusions:
No exothermic reaction was observed up to the melting point of the substance.
Executive summary:

When tested in a Grewer oven, the substance showed no exothermic reaction up to the melting point of the substance. The heating was applied in a linear rate of 0.5 K/min and 20 l/h of air.

Description of key information

When tested in a Grewer oven, the substance showed no exothermic reaction up to the melting point of the substance. The heating was applied in a linear rate of 0.5 K/min and 20 l/h of air.

Key value for chemical safety assessment

Additional information