Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Emergency measure - Inhalation: General emergency measures for keeping the respiratory tract
open.
Emergency measure - Eyes: Immediately flush opened eyes with plenty of water. Get
medical attention.
Emergency measure - Skin: Immediately wash off with plenty of water and soap. Remove
contaminated clothing.
Emergency measure - Ingestion: Induce drinking of water. Get medical attention.

Fire-fighting measures

Recommended extinguishing agent: Powder, foam, spray water or water mist. Fire extinguisher:
carbon dioxide, powder, water.

Product arising from burning: Formation of toxic combustion gases or vapours like carbon
monoxide, carbon dioxide and nitrogen oxides is possible in
the event of fire.

Product determined by test: N

Protective equipment: Suitable chemical protective clothing and self-contained
breathing apparatus.

Accidental release measures

Emergency measures in case of spillage: 1. Evacuate all persons from dangerous area. In case of a

higher amount of spilt liquid warn also persons in the

vicinity.

2. Ensure appropriate ventilation in an explosion-proof

manner.

3. Remove or switch off all potential sources of ignition.

4. Damaged containers must be put into a safety container

or the leakage must be reduced by sand or other

appropriate materials.

5. Prevent liquid from entering sewage system or surface/

ground water.

6. Absorb small amounts of spilt liquid with suitable ab-

sorption material and collect it in a tightly closed

container which must be labelled according to TRGS 201.

7. Higher amounts of spilt liquid should be collected by an
explosion-proof pump into a tightly closed and labelled

container.

8. Dispose of contaminated absorbents as EWC 150202* - ab-

sorbents, filter materials (including oil filters not

otherwise specified), wiping cloths, protective clothing
contaminated by dangerous substances.

9. Dispose not spilt T2954 as EWC 070508* - other still

bottoms and reaction residues.

10. While taking up the spilt material and cleaning the pol-
luted area avoid skin and eye contact as well as inhala-
tion of the substance by wearing appropriate personal

protective equipment (see section 'Handling').

Handling and storage

Handling: 1. Measurement for Exposure control and personal protection
All work processes must always be designed so that exposure
to the substance by inhalation and skin or mucosa contact is
as low as possible.

The substance should only be handled in closed systems.
Personal protective equipment:

Respiratory protection: required when vapours are generated
(Filter A (EN 149), cartridge color code black (NIOSH))

Hand protection: tested protective gloves (KCL, Butoject)
Eye protection: safety goggles

Skin protection: required.


2. Industrial hygiene

Adequate washing facilities and conspicuously labelled eye-
douche stations should be provided in the immediate vicini-
ty of the working area.

Immediately remove contaminated clothing.

Apply skin-protection barrier cream.

Wash hands and face after working.

Under no circumstances eat or drink at workplace.


3. Information related to protection against fire and explo-
sion

Highly flammable vapours may form. Keep away from potential
ignition sources. Protect against the effect of heat. Static
discharges must be avoided, e. g. through the earthing of
containers, apparatus, pumps and extraction devices.

Storage: Store the substance in the original packing drums or other
secure containers which are labelled according to the regu-
lations. Keep them tightly closed and secure them against
falling by taking the appropriate measures.

Avoid residues on the outside of the containers.

Store in a cool (8 °C because of product quality) and well-
ventilated area.

Remove all potential sources of ignition.

Packaging of the substance and or preparation: IBC (capacity: max. 1000 l), Drum (capacity: max. 200l). The
used vessels are proofed in accordance to the regulation of
the transportation of dangerous goods.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: UN-Nr. 1993
Transport: The product should be transported only in well closed secure
containers which are labelled according to the regulations.
They must be protected against falling by taking the appro-
priate measures.


Transport Code:

Road/Railway (ADR/RID): Name: flammable liquid, n.o.s.,
class 3, PG II, HI No. 33;

Air (IATA/DGR): Proper Shipping Name: flammable liquid,
n.o.s., class 3, PG II.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: Not relevant.

Chemical reaction with water: No reaction with water.

Dust explosion: Not relevant, liquid.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Recovery by mechanical collection.

Industry - Possibility of neutralisation: Neutralisation, not specified.

Industry - Possibility of destruction: controlled discharge: Removal, not specified.

Industry - Possibility of destruction - incineration: Incinerator with flue gas scrubbing.

Industry - Possibility of destruction - water purification: Pre-treatment before discharge to sewage works is not
necessary. The concentration in waste water depends on local
requirements.

Industry - Possibility of destruction - other: Not relevant.

Public at large - Possibility of recovery/recycling: Recovery by mechanical collection.

Public at large - Possibility of neutralisation: Neutralisation, not specified.

Public at large - Possibility of destruction: controlled discharge: Removal, not specified.

Public at large - Possibility of destruction - incineration: Incinerator with flue gas scrubbing.

Public at large - Possibility of destruction - water purification: Pre-treatment before discharge to sewage works is not
necessary. The concentration in waste water depends on local
requirements.

Public at large - Possibility of destruction - others: Not relevant.