Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Endpoint:
vapour pressure
Type of information:
calculation (if not (Q)SAR)
Remarks:
Migrated phrase: estimated by calculation
Adequacy of study:
key study
Study period:
2007-04-10
Reliability:
1 (reliable without restriction)
Cross-reference
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
other: Expert statement
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
yes
Remarks:
theoretical calculation
Principles of method if other than guideline:
Modified Grain Method (Lyman, 1985)
GLP compliance:
no
Type of method:
other: US EPA EpiWin v3.12 Calculation

Test material

Constituent 1
Details on test material:
NA

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Calculated value for EVA-KET by US EPIWIN v3.12

Any other information on results incl. tables

NA

Applicant's summary and conclusion

Conclusions:
As the available experimental methods allow a determination of vapour pressures down to 1.0E-05 Pa only, no meaningful experimental determination of the vapour pressure for AVE 5530 EVA-KET was possible. Therefore, in accordance with the respective EC guideline, no experimental determination of the vapour pressure for AVE 5530 EVA-KET is required.
Executive summary:

The vapour pressure of AVE 5530 EVA-KET at 25 °C was estimated to be 4.09E-11 mm Hg corresponding to 5.45E-09 Pa (using the Modified Grain method).