Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 202-710-8 | CAS number: 98-88-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Hydrolysis
Administrative data
- Endpoint:
- hydrolysis
- Type of information:
- experimental study
- Adequacy of study:
- other information
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- other: see 'Remark'
- Remarks:
- The authors tested the hydrolysis of benzoyl chloride by measuring the decrease in pH solution as HCl and benzoic acid are formed. GLP standards are not specified. The study sufficiently describes the materials and methodology used, thus the study can be considered Klimisch 2e as it is well documented, meets generally accepted scientific principles and is acceptable for assessment.
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 1 981
- Report date:
- 1981
Materials and methods
- Principles of method if other than guideline:
- Hydrolysis of benzoyl chloride was followed by measuring the decrease in solution pH values as HCl and benzoic acid were formed. Benzotrichloride was included in these experiments as a control. Since hydrolysis of benzoyl chloride is expected to be very rapid in the initial stages (0.1 min) and thus not observable by HPLC since a minimum sample preparation and HPLC injection time of 20 sec was needed, estimation based on pH measurements was chosen as method.
- GLP compliance:
- no
Test material
- Reference substance name:
- Benzoyl chloride
- EC Number:
- 202-710-8
- EC Name:
- Benzoyl chloride
- Cas Number:
- 98-88-4
- Molecular formula:
- C7H5ClO
- IUPAC Name:
- benzoyl chloride
- Details on test material:
- - Name of test material: benzoyl chloride
- Supplier: Malinckrodt
- Analyzed reagent grade
No more data available
Constituent 1
- Radiolabelling:
- no
Study design
- Analytical monitoring:
- no
Duration of test
- Temp.:
- 25 °C
- Initial conc. measured:
- 100 mg/L
Results and discussion
- Transformation products:
- yes
Identity of transformation products
Reference
- Reference substance name:
- Unnamed
- IUPAC name:
- benzoic acid
- Inventory number:
- InventoryMultipleMappingImpl [inventoryEntryValue=EC 200-618-2]
- CAS number:
- 65-85-0
- Identity:
- Benzoic acid
- Molecular formula:
- C7H6O2
- Molecular weight:
- 122.121
- SMILES notation:
- OC(=O)c1ccccc1
- InChl:
- InChI=1/C7H6O2/c8-7(9)6-4-2-1-3-5-6/h1-5H,(H,8,9)
Dissipation DT50 of parent compound
- Temp.:
- 25
- DT50:
- < 0.25 min
- Remarks on result:
- other: Calculated hydrolysis rate constant >2.77 min-1
Applicant's summary and conclusion
- Validity criteria fulfilled:
- not applicable
- Conclusions:
- The authors tested the hydrolysis of benzoyl chloride by measuring the decrease in pH solution at ~25°C as HCl and benzoic acid are formed. Under these conditions the half-life value was <0.25 min at 25°C. Using the formula t1/2 = ln 2 / (kH20), the hydrolysis rate constants calculated was > 2.77 min-1.
GLP standards are not specified. The study sufficiently describes the materials and methodology used, thus the study can be considered Klimisch 2e as it is well documented, meets generally accepted scientific principles and is acceptable for assessment. - Executive summary:
The authors tested the hydrolysis of benzoyl chloride (CAS n° 98-88-4) by measuring the decrease in pH solution at ~25°C as HCl and benzoic acid are formed. Initial concentration of the test substance was 100 ppm and hydrolysis reaction was monitored till no change in pH was evident. The half-life value was estimated using benzotrichloride which was included in this experiment as a control and aid to interpret the pH plots. Under these conditions the half-life value was 0.25 min at 25°C. Using the formula t1/2 = ln 2 / (kH20), the hydrolysis rate constants calculated was >2.77 min-1.
GLP standards are not specified. As the study sufficiently describes the materials and methodology used, the study can be considered reliable with restrictions as it is well documented, meets generally accepted scientific principles and is acceptable for assessment (Klimisch 2e).
.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.