Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 405-800-7 | CAS number: 27955-94-8 THPE; TRIS(P-HYDROXYPHENYL)ETHANE; TRIS(PARA-HYDROXYPHENYL)ETHANE
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
- Deviations:
- no
- Remarks:
- The study was conducted according to the test guidelines in effect at the time of study conduct.
- GLP compliance:
- yes
- Analytical monitoring:
- not specified
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: Test substance was dispersed in test water (nominal concentration 20 mg/L) by stirring overnight with the aid of a magnetic stirrer at 30ºC. The preparation was cooled to test temperature (22ºC) before use to give the stock solution.
- Controls: Aged, dechlorinated tap water
- Evidence of undissolved material (e.g. precipitate, surface film, etc): not reported - Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Laboratory culture: A synthetic sewage was prepared by dissolving the following ingredients per litre of dilution water:
16 g peptone
11 g meat extract
3 g urea
0.7 g NaCl
0.4 g CaCl2.2H2O
0.2 g MgSO4.7H2O
2.8 g K2HPO4
- Method of cultivation:
- Preparation of inoculum for exposure: At time "0", 16 ml of synthetic sewage was made up to 300 mL with water in a 1 litre glass beaker. 200 mL inoculum were added and the mixture aerated at approximately 0.5-1 liter per minute with compressed air via an airstone.
- Pretreatment: none
- Initial biomass concentration: not reported - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Hardness:
- Dilution water hardness was approximately 120-180 mg/L as CaCO3
- Test temperature:
- 22ºC
- pH:
- Activated sewage sludge pH was 8.3 and the dilution water pH was 7.5; no adjustment of pH was done.
- Dissolved oxygen:
- 2.5-6.5 mg O2/L
- Salinity:
- not reported
- Nominal and measured concentrations:
- Nominal concentration: 11 mg/L, the highest concentration attainable under the conditions of the study
- Details on test conditions:
- TEST SYSTEM
- Test vessel: 1 litre glass beaker
- Type (delete if not applicable): open
- Material, size, headspace, fill volume: Glass, 1 litre, headspace 500 mL, fill volume 500 mL
- Aeration: 0.5-1 litre per minute with compressed air via an airstone
- No. of vessels per concentration (replicates): 2
- No. of vessels per control (replicates): 2
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: Laboratory tap water, dechlorinated by passage through activated carbon and sofetned by reverse osmosis. Water parameters for the lab are not given in this report, but are available in other reports from approximately the same time frame.
OTHER TEST CONDITIONS
- Adjustment of pH: not adjusted
- Photoperiod: 3 h exposure under normal laboratory lighting
- Light intensity: not reported
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) : Oxygen consumption rates for 3 hours
TEST CONCENTRATIONS
- Spacing factor for test concentrations: not applicable; only one concentration was used
- Justification for using less concentrations than requested by guideline: The highest concentration that could be achieved was used - Reference substance (positive control):
- yes
- Remarks:
- 3,5-Dichlorophenol (purity 97%); nominal concentrations 3.2, 10, and 32 mg/L
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 11 mg/L
- Nominal / measured:
- estimated
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Duration:
- 3 h
- Dose descriptor:
- EC10
- Effect conc.:
- > 11 mg/L
- Nominal / measured:
- estimated
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- respiration rate
- Details on results:
- - Any observations (e.g. precipitation) that might cause a difference between measured and nominal values: not reported
- Effect concentrations exceeding solubility of substance in test medium: not reported - Results with reference substance (positive control):
- - Results with reference substance valid? yes
- Relevant effect levels: At 3.2 mg/L, the O2 consumption rate was 0.843 mgO2/L/min and inhibition was 2%. At 10 mg/L, the O2 consumption rate was 0.738 mgO2/L/min and inhibition was 14%. At 32 mg/L, the O2 consumption rate was 0.355 mgO2/L/min and inhibition was 59%. - Reported statistics and error estimates:
- not reported
- Validity criteria fulfilled:
- yes
- Conclusions:
- The EC50 ( respiration inhibition) value for the test substance with activated sewage sludge has been determined as >11 mg/L for the 3 hour contact time.
- Executive summary:
A study was performed to assess the inhibitory effect of the test substance on the respiration of activated sewage sludge. The study was conducted in accordance with the OECD Guideline for Testing of Chemicals No. 209, "Activated Sludge, Respiration Inhibition Test". Cultures of activated sewage sludge were incubated with synthetic sewage under vigorous aeration and in the presence of the test substance. Aeration was interrupted after 3 hours and the rates of respiration measured electrochemically for each culture. Percent inhibition of respiration was calculated for each culture after a 3 hour contact period by comparing oxygen depletion rates for the test substance with those for the negative control culture. A positive control, 3,5-dichlorophenol, was tested concurrently with the test substance in order to demonstrate the satisfactory performance of the procedure. The EC50 (respiration inhibition) value for the test substance has been determined as >11 mg/L for the 3 hour contact time.
Reference
Description of key information
3-hour EC10 >11 mg/L
3-hour EC50 > 11 mg/L
Key value for chemical safety assessment
- EC50 for microorganisms:
- 11 mg/L
- EC10 or NOEC for microorganisms:
- 11 mg/L
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.