Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 273-992-8 | CAS number: 69416-61-1
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Guidance on Safe Use
Administrative data
First-aid measures
Inhalation: If inhaled, remove to fresh air. - Ingestion: If swallowed, rinse mouth with water (only if the person is conscious). - Skin contact: rinse with plenty of running water. Remove contaminated clothing and shoes. -Eye contact: Rinse with plenty of running water. - In all cases: Obtain medical attention if symptoms occur.
Fire-fighting measures
Small fire suitable: Use dry chemical or CO2. - Large fire suitable : Use dry chemical powder. alcohol-resistant foam. - Unusual fire/explosion hazards : Fine dust clouds may form explosive mixtures with air. - Hazardous termal decomposition products : In case of fire, may produce hazardous decomposition products such as carbon monoxide, carbon dioxide, nitrogen oxides (NO, NO2), ammonia (NH3), amines, potassium oxide. - Special fire-fighting procedures : Fight fire from protected location or maximum possible distance. Keep the area surrounding the fire cool. - Protection of fire-fighters : Wear suitable protective clothing. Self-contained breathing apparatus.
Accidental release measures
Personal precautions : Avoid creating dusty conditions and prevent wind dispersal. Use suitable protective equipment. Keep away from sources of ignition. Take precautionary measures against static discharges. Use explosion-proof electrical (ventilating, lighting and material handling) equipment.- Environmental precautions : Prevent entry into sewers, basements or confined areas. Dyke if necessary. - Clean-up Methods:
Small spill and leak (Vacuum or sweep up material and place in a designated labelled waste container. Clean up affected area with a large amount of water). Large spill and leak (Use explosion-proof electrical - ventilating, lighting and material handling - equipment).
Handling and storage
This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 17(3) for on-site isolated intermediates and, in case the substance is transported to other sites for further processing, the substance should be handled at these sites under the Strictly Controlled Conditions as specified in REACH regulation Article 18(4). Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each manufacturing site.
Written confirmation of application of Strictly Controlled Conditions has been received from every affected Distributor and Downstream Processor/User of the Registrant’s intermediate.
Handling : Use with adequate ventilation. Local exhaust ventilation should be provided. Avoid creating dusty conditions and prevent wind dispersal. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Take measures against static discharge. Keep away from sources of ignition. Storage : Store in a fireproof location. Keep away from incompatible materials and avoid specific conditions (Keep away from heat, sparks and flame. Prevent formation of dust clouds). Keep container tightly closed and dry. Keep away from heat and direct sunlight.
Transport information
Land transport (UN RTDG/ADR/RID)
- UN number:
- not regulated
Shippingopen allclose all
SpecialProvisionsopen allclose all
Inland waterway transport (UN RTDG/ADN(R))
- UN number:
- not regulated
Shippingopen allclose all
Remarksopen allclose all
Marine transport (UN RTDG/IMDG)
- UN number:
- not regulated
Shippingopen allclose all
Remarksopen allclose all
Air transport (UN RTDG/ICAO/IATA)
- UN number:
- not regulated
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all
Exposure controls / personal protection
This substance is handled under Strictly Controlled Conditions in accordance with REACH regulation Article 17(3) for on-site isolated intermediates and, in case the substance is transported to other sites for further processing, the substance should be handled at these sites under the Strictly Controlled Conditions as specified in REACH regulation Article 18(4). Site documentation to support safe handling arrangements including the selection of engineering, administrative and personal protective equipment controls in accordance with risk-based management systems is available at each manufacturing site.
Written confirmation of application of Strictly Controlled Conditions has been received from every affected Distributor and Downstream Processor/User of the Registrant’s intermediate.
Engineering measures : Use only with adequate ventilation. Local exhaust ventilation should be provided. Use explosion-proof electrical (ventilating, lighting and material handling) equipment.
Hygiene measures : When using do not eat, drink or smoke. Wash hands after handling compounds and before eating, smoking, using lavatory, and at the end of day.
Personal protective equipment - Production scale : Respiratory system: Wear dust protection mask P2). Skin and body: Working clothes.
Eyes : Safety glasses with side shields. Hands : Wear suitable gloves (Recommended material (s) : >8 hours (breakthrough time): Nitril rubber, butyl rubber, neoprene, Viton, PVC. Replace damaged gloves).
Advice on personal protection is applicable for high exposure levels. Select proper personal protection based on a risk assessment of the actual exposure situation.
Stability and reactivity
Stability : Stable under recommended storage and handling conditions.
Conditions to avoid : Keep away from heat, sparks and flame. Prevent formation of dust clouds.
Materials to avoid : No special recommendations.
Hazardous decomposition products : In case of fire:
Keep away from heat, sparks and flame. Prevent formation of dust clouds.
Disposal considerations
Methods of disposal (waste of residues; contaminated packaging). : Waste must be disposed of in accordance with national and local environmental regulations.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.